  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Public",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the “Program” mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
        "title": "General Security Recommendations"
      },
      {
        "category": "general",
        "text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
        "title": "For More Information"
      },
      {
        "category": "legal_disclaimer",
        "text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND.  SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
        "title": "LEGAL DISCLAIMER"
      },
      {
        "category": "general",
        "text": "Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
        "title": "About Schneider Electric"
      },
      {
        "category": "summary",
        "text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert, Modicon M340, Momentum, MC80, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability & safety solutions. The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. The Modicon MC80 provides optimized operation, withstanding extreme conditions with high reliability and performance. The Modicon Momentum supports control and distributed I/O system with 4 fundamental components that easily snap together in various combinations to form versatile control systems or sub-systems. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers). Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality and integrity of the controller.",
        "title": "Overview"
      },
      {
        "category": "other",
        "text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric's [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch."
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cpcert@se.com",
      "name": "Schneider Electric CPCERT",
      "namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
    },
    "references": [
      {
        "category": "self",
        "summary": "EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety - SEVD-2023-010-06 PDF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
      },
      {
        "category": "self",
        "summary": "EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety - SEVD-2023-010-06 CSAF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2023-010-06.json"
      },
      {
        "category": "external",
        "summary": "Recommended Cybersecurity Best Practices",
        "url": "https://www.se.com/in/en/download/document/7EN52-0390/"
      }
    ],
    "title": "EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety",
    "tracking": {
      "current_release_date": "2026-04-14T07:00:00.000Z",
      "generator": {
        "date": "2026-04-13T14:37:45.844Z",
        "engine": {
          "name": "Schneider Electric CSAF Generator",
          "version": "1.2"
        }
      },
      "id": "SEVD-2023-010-06",
      "initial_release_date": "2023-01-10T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2023-01-10T00:00:00.000Z",
          "number": "1.0.0",
          "summary": "Original Release"
        },
        {
          "date": "2023-03-14T06:30:00.000Z",
          "number": "2.0.0",
          "summary": "Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7)."
        },
        {
          "date": "2023-08-08T15:41:00.000Z",
          "number": "3.0.0",
          "summary": "All versions of the EcoStruxure™ Process Expert are impacted by this vulnerability"
        },
        {
          "date": "2024-01-09T00:00:00.000Z",
          "number": "4.0.0",
          "summary": "A remediation is available for Modicon M580"
        },
        {
          "date": "2024-08-13T00:00:00.000Z",
          "number": "5.0.0",
          "summary": "A remediation is available for Modicon M580 CPU Safety(page 2)."
        },
        {
          "date": "2026-04-14T07:00:00.000Z",
          "number": "6.0.0",
          "summary": "Remediations are available for EcoStruxure Control Expert, Modicon Momentum, and Modicon M340."
        }
      ],
      "status": "final",
      "version": "6.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:generic/<16.2 HF003",
                "product": {
                  "name": "EcoStruxure™ Control Expert Versions prior to V16.2 HF003",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure™ Control Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "16.2 HF003",
                "product": {
                  "name": "EcoStruxure™ Control Expert Version V16.2 HF003",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure™ Control Expert"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:generic/<SV3.70",
                "product": {
                  "name": "Modicon M340 CPU Firmware versions prior to SV3.70",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M340 CPU"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "SV3.70",
                "product": {
                  "name": "Modicon M340 Firmware Version SV3.70",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M340 CPU"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:generic/<SV4.20",
                "product": {
                  "name": "Modicon M580 CPU versions prior to SV4.20",
                  "product_id": "6",
                  "product_identification_helper": {
                    "model_numbers": [
                      "BMEP*",
                      "BMEH*"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M580 CPU"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "SV4.20",
                "product": {
                  "name": "Modicon M580 CPU Version SV4.20",
                  "product_id": "7",
                  "product_identification_helper": {
                    "model_numbers": [
                      "BMEP*",
                      "BMEH*"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M580 CPU"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:generic/<SV4.21",
                "product": {
                  "name": "Modicon M580 CPU Safety Versions prior to SV4.21",
                  "product_id": "8",
                  "product_identification_helper": {
                    "model_numbers": [
                      "BMEP58*S",
                      "BMEH58*S"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M580 CPU Safety"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "SV4.21",
                "product": {
                  "name": "Modicon M580 CPU Safety Version SV4.21",
                  "product_id": "9",
                  "product_identification_helper": {
                    "model_numbers": [
                      "BMEP58*S",
                      "BMEH58*S"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon M580 CPU Safety"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:generic/<SV2.90",
                "product": {
                  "name": "Modicon Momentum Unity M1E Processor Firmware Versions prior to SV2.90",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon Momentum Unity M1E Processor"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "SV2.90",
                "product": {
                  "name": "Modicon Momentum Unity M1E Processor Firmware Version SV2.90",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon Momentum Unity M1E Processor"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Modicon MC80 All versions",
                  "product_id": "12",
                  "product_identification_helper": {
                    "model_numbers": [
                      "BMKC80"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "Modicon MC80"
          },
          {
            "category": "product_name",
            "name": "Modicon Momentum Unity M1E Processor",
            "product": {
              "name": "Modicon Momentum Unity M1E Processor (171CBU*)",
              "product_id": "13",
              "product_identification_helper": {
                "model_numbers": [
                  "171CBU*"
                ]
              }
            }
          },
          {
            "category": "product_name",
            "name": "Modicon M340",
            "product": {
              "name": "Modicon M340 CPU (part numbers BMXP34*)",
              "product_id": "14",
              "product_identification_helper": {
                "model_numbers": [
                  "BMXP34*"
                ]
              }
            }
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Modicon M340 Firmware versions prior to SV3.70 installed on Modicon M340 CPU (part numbers BMXP34*)",
          "product_id": "15"
        },
        "product_reference": "3",
        "relates_to_product_reference": "14"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Modicon M340 Firmware Version SV3.70 installed on Modicon M340 CPU (part numbers BMXP34*)",
          "product_id": "16"
        },
        "product_reference": "5",
        "relates_to_product_reference": "14"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Modicon Momentum Unity M1E Processor Firmware Versions prior to SV2.90 installed on Modicon Momentum Unity M1E Processor (171CBU*)",
          "product_id": "17"
        },
        "product_reference": "10",
        "relates_to_product_reference": "13"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Modicon Momentum Unity M1E Processor Firmware Version SV2.90 installed on Modicon Momentum Unity M1E Processor (171CBU*)",
          "product_id": "18"
        },
        "product_reference": "11",
        "relates_to_product_reference": "13"
      }
    ]
  },
  "vulnerabilities": [
    {
      "acknowledgments": [
        {
          "names": [
            "Daniel dos Santos",
            "Jos Wetzels"
          ],
          "organization": "Forescout Technologies"
        }
      ],
      "cve": "CVE-2022-45789",
      "cwe": {
        "id": "CWE-294",
        "name": "Authentication Bypass by Capture-replay"
      },
      "notes": [
        {
          "category": "description",
          "text": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could\r\ncause execution of unauthorized Modbus functions on the controller when hijacking an\r\nauthenticated Modbus session.",
          "title": "CVE Description"
        },
        {
          "category": "details",
          "text": "CVSS v4.0 Base Score 9.2 | Critical | [CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)",
          "title": "CVSS v4.0  Score"
        }
      ],
      "product_status": {
        "fixed": [
          "2",
          "7",
          "9",
          "16",
          "18"
        ],
        "known_affected": [
          "1",
          "6",
          "8",
          "12",
          "15",
          "17"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Firmware SV4.20 includes a fix for this vulnerability and is available for download here:https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
          "product_ids": [
            "6"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "Firmware SV4.21 includes a fix for this vulnerability and is available for download here:https://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-and-firmware Important: customer needs to use the version of EcoStruxure™ Control Expert v16.0 HF001 minimum to connect with the latest version of M580 CPU Safety. The software is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "EcoStruxure™ Control Expert V16.2 HF003 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware"
        },
        {
          "category": "vendor_fix",
          "details": "Firmware SV2.90 includes a fix for this vulnerability and is available for download here:https://www.se.com/ww/en/product-range/535-modicon-momentum/?parent-category-id=3900&parent-subcategory-id=3930&filter=business-1-industrial-automation-and-control#products",
          "product_ids": [
            "17"
          ],
          "restart_required": {
            "category": "system"
          },
          "url": "https://www.se.com/ww/en/product-range/535-modicon-momentum/?parent-category-id=3900&parent-subcategory-id=3930&filter=business-1-industrial-automation-and-control#products"
        },
        {
          "category": "vendor_fix",
          "details": "Version 3.70 of Modicon M340 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware",
          "product_ids": [
            "15"
          ],
          "restart_required": {
            "category": "system"
          },
          "url": "https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware"
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations to reduce the risk of exploit:• Setup a VPN between the Modicon PLC controllers and the engineering workstation containing EcoStruxureTM Control Expert. Note: this functionality may be provided by an external IPSEC compatible firewall located close to the controller.• Harden the workstation running EcoStruxure™ Control Expert.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation then they are encouraged to immediately apply the following mitigations to reduce the risk of exploit:\r\n• Setup an application password in the project properties.\r\n• Setup network segmentation and implement a firewall to\r\nblock all unauthorized access to port 502/TCP.\r\n• Configure the Access Control List following the\r\nrecommendations of the user manuals:\r\no “Modicon M340 for Ethernet Communications\r\nModules and Processors User Manual” in chapter\r\n“Messaging Configuration Parameters”:\r\nhttps://www.se.com/ww/en/download/document/31007131K01000/\r\n• Setup a secure communication according to the following\r\nguideline “Modicon Controllers Platform Cyber Security\r\nReference Manual,” in chapter “Setup secured communications”:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001999/\r\n• Consider the use of external firewall devices such as\r\nEAGLE40-07 from Belden to establish VPN connections for\r\nM340 & M580 architectures. For more details refer to the\r\nchapter “How to protect M580 and M340 architectures with\r\nEAGLE40 using VPN”:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001999/",
          "product_ids": [
            "15"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/31007131K01000/"
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation, it is recommended to apply the following mitigations to reduce the risk of the exploit:• Setup an application password in the project properties. • Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP. • Configure the Access Control List following the recommendations of the user manuals: o “Modicon M580, Hardware, Reference Manual”: https://www.se.com/ww/en/download/document/EIO0000001578/ • Setup a secure communication according to the following guideline “Modicon Controllers Platform Cyber Security Reference Manual,” in chapter “Setup secured communications”: https://www.se.com/ww/en/download/document/EIO0000001999/ o use a BMENOC module and follow the instructions to configure IPSEC feature as described in the guideline “Modicon M580 - BMENOC03.1 Ethernet Communications Schneider Electric Security Notification Module, Installation and Configuration Guide” in the chapter “Configuring IPSEC communications”: https://www.se.com/ww/en/download/document/HRB62665/ OR • Use a BMENUA0100 module and follow the instructions to configure IPSEC feature as described in the chapter “Configuring the BMENUA0100 Cybersecurity Settings”: https://www.se.com/ww/en/download/document/PHA83350 OR • Consider use of external firewall devices such as EAGLE40-07 from Belden to establish VPN connections for M340 & M580 architectures. For more details refer to the chapter “How to protect M580 and M340 architectures with EAGLE40 using VPN”: https://www.se.com/ww/en/download/document/EIO0000001999/ • Ensure the M580 CPU is running with the memory protection activated by configuring the input bit to a physical input, for more details refer to the following guideline “Modicon Controllers Platform Cyber Security Reference Manual”, “CPU Memory Protection section”: https://www.schneiderelectric.com/en/download/document/EIO0000001999/ o NOTE: The CPU memory protection cannot be configured with M580 Hot Standby CPUs. In such cases, use IPsec encrypted communication.",
          "product_ids": [
            "6"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/EIO0000001578/"
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation then they are encouraged to immediately apply the following mitigations to reduce the risk of exploit:\r\n• Setup an application password in the project properties.\r\n• Setup network segmentation and implement a firewall to\r\nblock all unauthorized access to port 502/TCP.\r\n• Configure the Access Control List following the\r\nrecommendations of the user manuals:\r\no “Modicon M580, Hardware, Reference Manual”:\r\nhttps://www.se.com/ww/en/download/document/EIO0\r\n000001578/\r\n• Setup a secure communication according to the following\r\nguideline “Modicon Controllers Platform Cyber Security\r\nReference Manual,” in chapter “Setup secured\r\ncommunications”:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001\r\n999/\r\no use a BMENOC module and follow the instructions to\r\nconfigure IPSEC feature as described in the guideline\r\n“Modicon M580 - BMENOC03.1 Ethernet\r\nCommunications Schneider Electric Security\r\nNotification Module, Installation and Configuration\r\nGuide” in the chapter “Configuring IPSEC\r\ncommunications”: \r\nOR\r\n• Use a BMENUA0100 module and follow the instructions to\r\nconfigure IPSEC feature as described in the chapter\r\n“Configuring the BMENUA0100 Cybersecurity Settings”:\r\nhttps://www.se.com/ww/en/download/document/PHA83350\r\nOR\r\n• Consider use of external firewall devices such as EAGLE40-\r\n07 from Belden to establish VPN connections for M340 &\r\nM580 architectures. For more details refer to the chapter\r\n“How to protect M580 and M340 architectures with EAGLE40\r\nusing VPN”:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001\r\n999/\r\n• Ensure the M580 CPU is running with the memory protection\r\nactivated by configuring the input bit to a physical input, for\r\nmore details refer to the following guideline “Modicon\r\nControllers Platform Cyber Security Reference Manual”,\r\n“CPU Memory Protection section”: https://www.schneiderelectric.com/en/download/document/EIO0000001999/\r\no NOTE: The CPU memory protection cannot be\r\nconfigured with M580 Hot Standby CPUs. In such\r\ncases, use IPsec encrypted communication.\r\nTo further reduce the attack surface on Modicon M580 CPU Safety:\r\no Ensure the CPU is running in Safety mode and\r\nmaintenance input is configured to maintain this\r\nSafety mode during operation – refer to the document\r\nModicon M580 - Safety System Planning Guide - in\r\nthe chapter “Operating Mode Transitions”:\r\nhttps://www.se.com/ww/en/download/document/QGH60283/",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/EIO0000001578/"
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation then they are encouraged to immediately apply the following mitigations to reduce the risk of exploit:\r\n• Setup an application password in the project properties\r\n• Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n• Configure the Access Control List following the recommendations of the user manuals:• “Momentum for EcoStruxure™ Control Expert – 171 CBU 78090, 171 CBU 98090, 171 CBU 98091 Processors” manual in the chapter “Modbus Messaging and Access Control”: https://www.se.com/ww/en/download/document/HRB44124/\r\n• Setup a secure communication according to the following guideline “Modicon Controllers Platform Cyber Security Reference Manual,” in chapter “Setup secured communications”: https://www.se.com/ww/en/download/document/EIO0000001999/",
          "product_ids": [
            "17"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/HRB44124/"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric is establishing a remediation plan for all future versions of Modicon MC80 controllers that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:\r\n• Setup an application password in the project properties\r\n• Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n• Configure the Access Control List following the recommendations of the user manuals:\r\n• “Modicon MC80 Programmable Logic Controller (PLC) manual” in the chapter “Access Control List (ACL)”: https://www.se.com/ww/en/download/document/EIO0000002071/\r\n• Setup a secure communication according to the following guideline “Modicon Controllers Platform Cyber Security Reference Manual,” in chapter “Setup secured communications”: https://www.se.com/ww/en/download/document/EIO0000001999/",
          "product_ids": [
            "12"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/EIO0000002071/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "6",
            "8",
            "12",
            "15",
            "17"
          ]
        }
      ],
      "title": "CVE-2022-45789"
    }
  ]
}